Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | Festo |
Model Number : | HEP-D-MIDI |
Certification : | cc |
Price : | RMB/100-10000/PC |
Payment Terms : | T/T |
Supply Ability : | 10PCS/days |
Delivery Time : | 3 work days |
Product Description:
Advantages and features of FESTO switch valve
No need for external energy: FESTO switch valve is an energy-saving
product that does not require external energy and uses the
temperature change of the controlled medium for automatic
adjustment.
High reliability:
FESTO switch valve adopts high-quality materials and precision
manufacturing technology, which can withstand the test of harsh
environments such as high temperature and high pressure to ensure
the stable operation of the equipment.
With a rich product series to meet different customer needs.
High efficiency performance:
FESTO switch valve can complete the switch action in a very short
time, thereby ensuring the smooth progress of the entire production
process.
The structural design fully considers the issue of energy
utilization. Through precise flow control and optimized circuit
design, it is achieved while meeting work needs while minimizing
energy consumption.
Good stability: FESTO switch valve has good anti-interference
ability and can maintain a stable working state in a complex
industrial environment.
High safety:
FESTO switch valve fully considers safety factors in design and
adopts multiple safety protection measures to ensure that the gas
source or power supply can be cut off in time under abnormal
circumstances to prevent accidents.
It also has fault self-diagnosis and early warning functions, can
monitor the working status in real time, and will immediately issue
an alarm once an abnormality is found, reminding the operator to
deal with it in time.
Wide range of applications: FESTO switch valves can meet the needs
of various media, and different types of switch valves can be
selected according to the needs of different industrial scenarios.
Energy saving and environmental protection: FESTO switch valves
adopt advanced energy-saving technology, which can minimize energy
consumption during use.
Precise control: FESTO switch valves can achieve precise flow
control and pressure regulation.
Compact structure: FESTO switch valves have a compact structure and
are easy to install.
Precautions for the use of FESTO switch valves
Selection:
It is very important to choose a suitable FESTO switch valve.
Different application scenarios have different performance
requirements for switch valves, including working pressure, flow,
medium temperature, etc. When selecting, the parameters of the
switch valve should be carefully checked to ensure that it meets
the needs of the specific system.
Installation:
Medium and electrical connection: For pneumatic switch valves, the
medium gas source should be oil-free, water-free, clean and free of
impurities. The electrical wiring should be carried out according
to the wiring diagram provided by FESTO to ensure correct wiring
and avoid electrical failures.
Installation location: The installation location of the switch
valve will also affect its performance. Avoid installation in
abnormal temperature environments, places with large vibrations,
and environments with corrosive gases. FESTO switch valves usually
have clear installation directions and location requirements.
Strict installation in accordance with the instructions will help
improve service life and reliability.
Debugging:
Leakage problem: Before the system is activated, debugging is a
critical link. Check whether the switch valve has leakage,
especially at the joints and sealing surfaces. Leakage not only
affects the efficiency of the system, but also may cause energy
waste.
Coil installation: The coil of the switch valve is a key component
for controlling the switch of the valve. During debugging, check
whether the switch valve coil is installed firmly and whether it is
well connected to the power supply. Too tight or too loose
installation will affect the operation of the switch valve and even
cause short circuit or damage.
Working pressure and flow adjustment: During the debugging process,
appropriate working pressure and flow are the key to ensure the
normal operation of the switch valve. Adjust the pressure and flow
control devices according to the system requirements to ensure that
the switch valve operates under optimal working conditions. If the
flow is too large or the pressure is too high, it may cause damage
to the valve body and even affect other components of the system.
Maintenance:
Cleaning and inspection: After the switch valve has been running
for a long time, it is easy to accumulate dust, oil and other
impurities, causing the valve to get stuck or run poorly. Regularly
cleaning and checking the various parts of the switch valve,
especially the sealing ring and valve body, can effectively extend
its service life. For pneumatic systems, the air filter should also
be cleaned regularly to ensure that the air source is clean.
Check the coil and circuit: The control coil of the switch valve is
the core of the electrical control part. Long-term use may cause
failures due to unstable current or poor contact. Regularly check
whether the electromagnetic coil is heated and whether the circuit
connection is firm to prevent electrical failures from affecting
the normal operation of the system.
Avoid overload operation: FESTO switch valves usually have a
certain load range. Overload operation will accelerate the loss of
the valve and even cause failures. When using, avoid working under
a large load for a long time. The working mode should be reasonably
adjusted according to the specific conditions of use to avoid
overload operation.
Fault handling:
Valve does not move: If the switch valve cannot move, first check
whether the power supply is normal and ensure that there is no
problem with the coil connection. If the power supply is normal,
check whether the switch valve is blocked or contaminated, and
clean or replace damaged parts if necessary.
Leakage problem: The reason for the leakage of the switch valve may
be aging of the sealing material or improper installation. For
leakage problems, the machine should be stopped for inspection in
time, and the sealing ring should be replaced or the installation
position should be readjusted if necessary.
Rated Flow | max 80 lpm |
End Connection | Female NPT |
After Warranty Service | Video technical support |
Color | Black |
Pressure | Hydraulic |
Material | Steel |
Weight | 1kg |
Seal Material | Nitrile |
Marketing Type | Hot Product 2019 |
Temperature Of Media | Normal Temperature |
FAQ
Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more
orders and give our clients more convener ,we accept small order.
Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we
can help you.
Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.
Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15
days for an order with MOQ qty.
Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry.
If you are very urgent to get the quotation.Please call us or tell
us in your mail, so that we could regard your inquiry priority.
![]() |