Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | DAIKIN |
Model Number : | KSO-G02-2DA-30-EN |
Certification : | cc |
Price : | RMB/100-10000/PC |
Payment Terms : | T/T |
Supply Ability : | 10PCS/days |
Delivery Time : | 3 work days |
Product Description:
Advantages and characteristics of DAIKIN solenoid valve
High reliability and safety
Eliminate external leakage and control internal leakage: DAIKIN
solenoid valve adopts advanced sealing technology, which can
effectively eliminate external leakage, and at the same time, the
control of internal leakage is also excellent, and it is safe to
use.
Anti-seismic, waterproof, and dustproof: It has the characteristics
of anti-seismic, waterproof, and dustproof, and can operate stably
in harsh environments.
Simple system and low price
Simple structure: The solenoid valve itself has a simple structure,
is easy to maintain, and has a relatively low price.
Low cost of automatic control system: The automatic control system
is simple and the cost is low.
Quick response and high efficiency performance
Quick action: DAIKIN solenoid valve has a fast response speed and
can complete the switching action in a short time.
Large flow control: Some models such as the V38A3RX-95 series can
achieve large flow control.
Diversified and high-performance design
Multiple models and specifications: Provide a variety of models and
specifications to meet the needs of different application
scenarios.
High pressure and high flow control: It can achieve high pressure
up to 35MPa and large flow control of 100/min (G02) or 160/min
(G03).
Dustproof and waterproof design: Most components are dustproof and
waterproof according to IEC Pub529 IP65 standard and comply with
European safety standards (CE).
Wide range of applications
Suitable for a variety of media: Suitable for a variety of fluid
media, including working oil containing petroleum components,
working oil containing water glycol, working oil containing
phosphate ester, etc.
Various application scenarios: Widely used in industrial
automation, hydraulic systems, pneumatic systems and other fields.
Precautions for the use of DAIKIN solenoid valves
Selection and medium requirements
Reasonable selection: Select the appropriate model according to the
process requirements, and pay attention to the pressure before and
after the valve and the set value conditions should be close to the
actual process conditions.
Medium cleanliness: The medium should be kept clean to avoid valve
failure due to impurities. For non-clean fluids, a filter should be
installed before the valve.
Installation and commissioning
Installation direction: The installation direction is not
restricted, but the springless solenoid valve should be installed
horizontally.
Flow direction mark: Pay attention to the flow direction mark on
the valve body to avoid wrong flow direction.
Clean the pipeline: Before installation, the pipeline should be
thoroughly cleaned with the valve fully open to prevent welding
slag and other debris from scratching the sealing surface.
Bypass pipe setting: Generally equipped with a bypass pipe to
facilitate continued operation when repairing or replacing the
valve.
Environment and temperature
Ambient temperature: It should be used in the range of ambient
temperature -15℃~50℃ and relative humidity 0%~95%.
Medium temperature: The medium temperature should be in the range
of -15℃~70℃, and when the oil temperature is significantly
different from the ambient temperature, attention should be paid to
thermal shock.
Maintenance and care
Regular inspection: Regularly check the seals and valve body of the
solenoid valve, and clean dust and impurities in time.
Anti-corrosion protection: Sandblast and rust-remove the valve
body, and electrostatically spray or apply non-toxic epoxy paint to
enhance the anti-corrosion performance.
Avoid continuous pressurization: Solenoid-operated valves and
solenoid pilot reversing valves should avoid being in the
high-pressure reversing position for a long time to prevent fluid
adhesion and poor operation.
Electrical and operation
Electrical connection: Ensure that the electrical connection is
correct and avoid exciting both ends of the solenoid valve at the
same time.
Excitation requirements: Springless solenoid valves require
continuous excitation to prevent the slide valve from reversing.
Through reasonable selection, correct installation and maintenance,
DAIKIN solenoid valves can perform excellent performance in various
industrial applications and ensure stable operation of the system.
With Gauges | -40 to 180°F / -40 to 82°C |
Sealing Class | IP 67 A |
Temperature | -20~80°C |
Thread Type | G |
Part Number | KSO-G02-2DA-30-EN |
Voltage | 12V |
Delivery | 1-3 Days |
Coil Insulation | Class H |
Core Tube | Stainless steel |
Watt | 1.2W, IP00/65 |
FAQ
Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more
orders and give our clients more convener ,we accept small order.
Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we
can help you.
Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.
Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15
days for an order with MOQ qty.
Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry.
If you are very urgent to get the quotation.Please call us or tell
us in your mail, so that we could regard your inquiry priority.
![]() |